Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Healicom Medical Equipment Co., Ltd.  

Health & Medicine

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Mrs. Alice
  • 电话:86-25-84452678
  • 传真:86-25-84452678
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > ICU Infusion Pump 820 Medical Equipment Portable Hospital Electric Automatic Portable Infusion Pump
ICU Infusion Pump 820 Medical Equipment Portable Hospital Electric Automatic Portable Infusion Pump
单价 $320.00 / Piece对比
询价 暂无
浏览 177
发货 Chinajiangsunanjing
库存 2000Piece
过期 长期有效
更新 2020-05-06 21:46
 
详细信息
Product Name: ICU Infusion Pump 820 Medical Equipment Portable Hospital Electric Automatic Portable Infusion Pump Certification: CE, ISO13485 Type: Infusion Pump Infusion Rate: 0.1m/H---1200mi/H (1ml/H Step) Rate Accuracy: Within+5 % (After Correct Calibration) Purge Rate: 100m/H---1200ml/H(Can Be Calibrated) Volume Limit: 0m1---9999ml Total Infusion Volume: 0---9999.9 Ml Power Source: 100---240V 50/60Hz;4 Hours Internal Battery Backup Trademark: Healicom Transport Package: Carton Specification: CE ISO Origin: Jiangsu, China Product Description ICU Medical Equipment Portable Hospital Electric Automatic Portable Infusion PumpProduct introduction1.Unique audible and visual alarm, safe and reliable, gain patents2.Compatible with any brand iv sets after correct calibration3.work mode:ml/h and drop/min. can switch freelyFeature:Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting etcHD LCD Display, high capacity words, friendly user interface, dynamically display working statusCompatible with any brand of infusion sets after correct calibrationPreset Solution Volume to greatly reduce the workload of nursesWork mode: mlI/h and drop/min can switch freelyThree levels of occlusion: high, middle and lowPurge functionAutomatically record the settings of last infusionSpecification:Infusion Rate 0.1m/h---1200mI/h (1ml/h step)Rate Accuracywithin+5 % (after correct calibration)Purge Rate100m/h---1200ml/h(can be calibrated)Volume Limit0m1---9999mlTotal Infusion Volume0---9999.9 mlAlarm PressureHigh:800mmHg±200mmHg(106.7kPa+26.7kPa)Medium:500mmHg± 100mmHg(66.7kPa+13.3kPa)Low:300mmHg±100mmHg(40.7kPa+13.3kPa)Alarmsend of injection, occlusion, door open, bubbles in the tube, wrong setting,low battery, AC power pulled out etcPower source100---240V 50/60Hz;4 hours internal battery backupBubble Detectorultrasonic wave detector, detection sensitivity≥25μLKVO Speed1m1/h--- 5ml/h (1ml/h step)Power Consumption18VAOperation EnvironmentTemperature +5----+40 degreeRelative Humidity 20----90%StorageTemperature -30----+ 55 degreeHumidity≤95%Atmospheric Pressure 50. 10KPa----106.0KPaWeight1.8kgDimension140mm (L)x 157mm (W)x 220mm (H)ForbiddenNot support blood InfusionPackage1pc per each Carton, 2.8KG; 24cm (L) x 26cm (W) x 31cm (H)2pc per each Carton, 5.8KG; 52cm (L) x 30cm (W) x 36cm (H)3pc per each Carton, 9KG; 76cm (L) x 30cm (W) x 36cm (H)